Sliding Gate Operator (1) (Set) (110v). Internal Hex-angular Bolt (4) (PCs). Left Limit Iron (1) (PCs).

Right Limit Iron (1) (PCs). 15ft of Steel Rack (5 PCs). Magnetic Limit Switch (1) (PCs). Inside Control Board (1) (PCs). Life-long repairing with charge offered.

Please read the instructions carefully before proceeding. MCU is supplied to control the gate operator. Keypad / single button interface. Photo beam safety beam interface. User can select Auto-close function.

Manual key release design for emergency purposes. Carefully read and follow all safety precaution. And warning before attempting to install and use this automatic gate operator. Make sure the Power supply(AC220V or AC110V) of the gate operator is suitable for the power supply in your area. Rated output power of motor.

30m / 100ft (Frequency:433.92mHz). 58.5mm / 2.3inch. The GPY600AC will handle gate weighting up to 600 kg and up to 8m / 26ft & 12m if the proper installation procedures have been followed. The GPY600AC gate operator operates by forcing a drive rack by a drive gear. The entire configuration is shown in the diagram below.

The gate operator must be installed on the inside of the gate. Be sure the gate is properly installed and slides smoothly before installing the G.

The gate must be plumb, level, and move freely. In order to protect the cable, use PVC conduit for low voltage power cable and control wires. Conduit must be preset into the concrete when it is poured. Wires within the conduit shall be located or protected so that no damage can result from contact with any rough or sharp part.

The base unit of the gate operator requires a concrete pad in order to maintain proper stability. The concrete pad should be approximately 450mm x 300mm x 200mm deep in order to provide for adequate weight and structure to insure proper stable installation. You can use anchor bolts, anchors, washers and nuts. These anchors must be set into the concrete when it is poured or you can use wedge anchors to fasten the operator.

After the concrete has hardened, mount the gate operator base to the concrete pad. Verify that the base is properly leveled. Using bolts and washers mount the gate operator to the base and insert the cover. Check the operator and make sure it is lined up with the gate. In the same package with rack.

Lay the first piece of rack on the gear and weld the first nut on the gate. Move the gate manually, checking if the rack is resting on the gear, and weld the second and third nut.

Bring another rack element near to the previous one. Move the gate manually and weld the three nuts as the first rack, thus proceeding until the gate is fully covered. When the rack has been installed, to ensure it meshes correctly with the gear. The space between rack and gear is about 0.5mm. To ensure safety, it is rec.

Ommended to install limit switches at both ends of the gate to prevent the gate from sliding out of the rails. The rails must be installed horizontally. Install the limit block as shown in Fig. The spring limit switch and blocks are used to control the position of the gate. Release the gear with the key and push the sliding gate manually to pre-determine the position, fix the block to the rack and lock the gear by push up the release bar.

Moving the gate electrically, adjust the block to the proper position. Until the position of the opening and closing meet the requirement. The magnetic of limit switch and blocks are used to control the position of the gate. In case of power failure use key unlock the lock and pull down the release bar about 90 degree to open or close gate manually, use the release key as follow.

Fit the supplied key in the lock. Turn the key and pull down the release bar about 90. Note: Do not exceed 90°, be careful not to use too much force, otherwise the release bar will be damaged. Open and close the gate manually. Note: If the gate bumps the mounting post and cannot be electric opened, move the gate a few inches by hand, thus you can release the gate with the key, open and close the gate manually.

Make sure that the power is OFF before making any electrical connections. Remove the cover, perform the wiring See Fig. 8 and wiring notes for control board and replace the cover again. Wiring notes of control board. Power Input(X1):E (Earth), L (Live), N (Neutral). Caution light: connect caution light wire toD1 and D2(terminal X3). Output power supply: 24VDC, COM (COM), I.

If the infrared beam is interrupted during closing, the gate will reverse and open immediately. The product is not factory equipped with an infrared device, the infrared output signal must be N. Three-button switch / single-button switch (keypad): The PY600AC is equipped with interfaces for three-button switch and single-button switch (keypad). To install the keypad attach one lead of your keypad to CLS of terminal X4 and the other to the COM. The keypad will function in single channel mode (the DIP switch 1 should be turn to OFF).

For three-button switch installation, use the terminals for multi-channel mode. Connect open wire of external button switch to OPN of terminal X4, connect close wire of switch to CLS, connect stop wire of switch to STP, connect common wire of switch to COM.

Motor and capacitor (Terminal X2, X3): V (com), U (Positive direction), W (Opposite direction), E (grounding), C (capacitor). The remote control works in a single channel mode. The function of button 1, button 2. With each press of the remote control button which has been programmed, the gate will close, stop, open or stop cycle.

You can program/learn button 1, button 2, button 3 individually. You also can program/learn two buttons or three buttons together, but you need repeat the program/learn process if you want to use more than one button.

Adding extra remote controls (Learn). Remove the cover, press the learn button AN1 Fig. 8, then the LED2 Fig. And turn off, then press the remote control button which you want to use, the LED2 will turn on about 2 seconds and then turn off again.

The learning process is finished. Up to 25 remote controls may be used.

To erase all existing remote controls, press and hold learn button AN1, the. LED2 turns on, release the button once the LED2 turns off. This indicates that all the remote controls have been erased completely.

Press the OPEN button of external button switch or remote control button which has been learned, the gate will open, the motor rotates clockwise, and the LED2. The output voltage between D1 and D2 (terminal X3) is AC220V/110V, the voltage between V and U is AC220V/110V.

Press STOP button or the same remote control button, the gate stops running. Then press CLOSE button or the same remote control button again, the gate will close, the motor rotates anticlockwise, and the LED2 is turns on.

The output voltage between D1 and D2 (terminal X3) is AC220V/110V, the voltage between V and W is AC220V/110V. Press the STOP button or the same remote control button, the gate stops running. And the LED2 is turns off. If the gate does not move in the desired direction, then you will need to reverse the motor operating direction, open the black plastic cover, you can do this by exchanging wires U and W, OPLT and CLLT. Single-button switch (the CLS and COM), OPN and COM is open door function also. When the 2 and 3 all ON, the Controller havent Auto-close function. When the 2 ON and the 3 is OFF, auto-close time is near 20 Sec.

When the 2 OFF and the 3 is ON auto-close time is near 40 sec. When the 2 and the 3 is all in position, the auto-close time is near 60 sec.

You must follow the operating instruction as above, any wrong operation is not allowed during setting. If your device responds to your requested function correctly, you have set the function successfully, otherwise repeat the above setup instruction until your device responds to your expected function. If the gate can not be moved, please check whether the gate is obstructed or the gate is too weight.

Activities Covered in this section. With each press of the button, the gate will close, stop, open or stop cycle. Three-button mode external button switch (not supply). Press OPEN button, the gate opens.

Press STOP button, the gate stops. Press CLOSE button, the gate closes. Single-button mode external button switch / keypad (not supply).

This feature can be selected to make the gate stay open for some seconds before it automatically closes. The auto-close time can be adjusted to between 15, 30 and 45 seconds.

If infrared beam is interrupted during closing, the gate will reverse and go open immediately. This feature will not function if the gate is in fully opened and closed positions or during opening. The gate will return to open if press OPEN button of external button switch during closing.

The switch is used to accurately stop the gate in the opened and closed positions. If the gate stops at opened position when the limit switch is reached, the gate will not move if you press OPEN button. If the gate stops at closed position when the limit switch is reached, the gate will not move if you press CLOSE button. The device is installed with a thermal protector, the thermal protector will switch off the motor automatically in case of the temperature is higher than 120°C and switch on the motor automatically when the temperature is lower than 85°C. Check the door once a month. The door should be carefully checked for balance. The door must be in good working order.

We suggest for safety reasons, photocells be used on all gates. Disconnect from mains supply before replacing bulb.

Be sure to read the entire manual before attempting to perform any installation or service to the door operator. Our company reserves the right to change the design and specification without prior notification.

The door fails to open and close. LED display does not light. Make sure that power is ON. The door can open, fails to close.

Infrared photocell function is enable, but the photocell has not been installed. Make sure the infrared photocell function is disable.

Remote transmitter does not work. Battery level may be low. Replace the battery inside the transmitter. The transmitter operating distance is too short.

After receiving the gate operator, you should make an unpack-inspection, in which you should check whether the product was damaged. If you have any problem please contact our dealer.

You should find the following items in our standard packing. The item "NSEE PY600 AC Residential Operator Rack and Pinions Slide Gate Door Opener" is in sale since Wednesday, May 18, 2016. This item is in the category "Home & Garden\Home Improvement\Building & Hardware\Garage Doors & Openers\Opener Systems".

The seller is "gate-hardware-and-equipments" and is located in Opa-Locka, Florida. This item can be shipped worldwide.

  • Horse Power: 1400 lbs (600 kgs)
  • Model: PY600ACU (110v)
  • Maximum Door Weight: 1400 lbs (600 kgs)
  • MPN: PY600ACU (110v) Kit 1
  • Maximum Gate Weight: 1400 lbs (600 kgs)
  • Brand: NSEE
  • Power Source: Electric
  • Type: Operator Rack and Pinions Slide Gate Door Opener
  • Motor Loading Weight: 1400 lbs (600 kgs)
  • Voltage: 110V (± 10%)


NSEE PY600 AC Residential Operator Rack and Pinions Slide Gate Door Opener    NSEE PY600 AC Residential Operator Rack and Pinions Slide Gate Door Opener